MK Mohit Kumar
Healthcare AI & Imaging Systems · 2026

Making AI safe, precise, & interoperable.

Bridging cutting-edge deep learning with clinical imaging workflows - from photon-counting CT detector physics to DICOMweb orchestration gateways and model-agnostic evaluation protocols.

Peer-Reviewed & Preprints 2026

Clinical Gravity.

Research has gravity.

Before neural networks enter the surgical suite or clinical reading console, preserve deterministic safety, sub-45ms latency, and vendor-neutral interoperability. Let precision enter your orbit of patient care.

Research In Action

Clinical systems, made precise.

Orchestration gateways, direct-conversion detector physics, and systematic evaluation protocols in one unified framework.

Systems Architecture

The 4-Layer Clinical Orchestrator

An open, model-agnostic bridge between enterprise hospital PACS archives and modern deep learning inference pipelines.

LAYER 1 · INGESTION & STORAGE

DICOM PS3.18 Native Gateway

Implements full DICOMweb RESTful bindings over standard HTTP verbs. Ingests heterogeneous clinical studies directly from modalities and enterprise PACS with zero metadata degradation.

    Empirical Validation

    Peer-evaluated accuracy & physics.

    Reproducible clinical evaluation protocols (E1-E4) alongside comparative detector semiconductor physics.

    Gateway Protocol (E1-E4)

    CPU Benchmark · Intel i5
    Experiment Primary Metric Observed Value Clinical Target
    E1 Latency p95 Ingest-to-Result 41.0 ms < 100 ms
    E1 Throughput Concurrent Volume 79.7 req/s > 25 req/s
    E2 Segmentation Sørensen-Dice (DSC) 0.696 Deterministic Mask
    E2 Boundary Hausdorff (HD95) 1.0 voxel ≤ 2.0 voxels
    E3 Grounding Spatial F1-Score 1.000 > 0.95
    E4 Round-Trip StudyInstanceUID 100% Preserved 100% Provenance

    PCCT Semiconductor Physics

    Detector Comparison
    Property Deep Silicon (GE) CdTe / CZT (Siemens) Canon Ultimion
    Stopping Power Edge-on geometry Very High (Z=48,52) High direct capture
    Hole Tailing / Bias Zero Polarization Polarization risk Compensated ASIC
    Pixel Pitch 0.14 mm 0.11 mm 0.16 mm
    Energy Bins Up to 8 Bins 4 Threshold Bins Multi-threshold
    Spectral Speed Sub-nanosecond Charge sharing corr. Fast readout ASIC
    PACS Bottleneck 8x Volume Data Multi-series DICOM High bandwidth req.

    Some notable milestones in our research.

    Open-source radiology informatics by the numbers, and what peers say.

    Mohit Kumar · Research Lab

    “A self-hosted, model-agnostic gateway achieving p95 latency of 41ms and 79.7 req/s throughput on commodity hardware with full STOW-RS and DICOM SR fidelity.”

    DICOMweb AI Gateway - Evaluation Protocol E1-E4
    3+

    Major Technical Reviews & Architecture Specs

    41ms

    p95 Inference & Ingestion Latency

    8+

    Analytical Figures on Photon-Counting Physics

    100%

    Vendor-Neutral DICOMweb & FHIR R4 Compliant

    Research Repository

    Filterable Research & Publications

    Preprints, clinical reviews, and open-source gateway repositories ready for citation and deployment.

    Let's advance imaging intelligence together.

    Available for clinical AI research collaborations, DICOMweb architecture consulting, and academic discussions.

    ESC